• 2000: 1 40A 50ohm PCB Mounting Current Transformer
  • 2000: 1 40A 50ohm PCB Mounting Current Transformer
  • 2000: 1 40A 50ohm PCB Mounting Current Transformer
  • 2000: 1 40A 50ohm PCB Mounting Current Transformer

2000: 1 40A 50ohm PCB Mounting Current Transformer

Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Samples:
US$ 0/10pcs 1 10pcs(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
ZMCT118A
Insulating Medium
Epoxy Resin
Installation
PCB Mounting
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Capacitive Type
N.W
13G
Inner Hole
7.5mm
Turns Ratio
2000:1
Transport Package
Cartons
Specification
ISO9001 ISO14001, CE, ROHS, SGS
Trademark
zeming
Origin
Nanjing, Jiangsu
HS Code
8504311000
Production Capacity
100.000PCS/Month

Product Description

    ZMCT118A  Current Transformer
Features and applications: Small size,high accuracy,good consistency,for current and power measurement
 
Structural parameters:

2000: 1 40A 50ohm PCB Mounting Current Transformer
                                          1,2pin: secondary output,3,4pin: empty pin
                            Front view                                            Bottom view
 
The main technical parameters:
model ZMCT118A
input current 0~40A(sampling resistor 50Ω)
Rated output current 2.5mA at 5A
turns ratio 2000:1
phase angle error ≤15'(input 5A,sampling resistor 50Ω)
linear range 0~40A(sampling resistor 50Ω)
linearity ≤0.1%(5%dot~120%dot)
Permissible error -0.2%≤f≤+0.2%(input 5A,sampling resistor 50Ω)
isolation voltage 4500V
application Current and power measurement
Encapsulation Epoxy
installation PCB mounting(Pin length>3mm)
operating temperature -40ºC~+85ºC

Direction for use:
2000: 1 40A 50ohm PCB Mounting Current Transformer
                    Figure I                                                                FigureII
 
1. ZMCT118A used for measurement. Typical usage is shown in Figure 1 and Figure 2. R is a sampling resistor.
2. Empty pin can not be grounded.
2000: 1 40A 50ohm PCB Mounting Current Transformer
2000: 1 40A 50ohm PCB Mounting Current Transformer
                 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now