• ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
  • ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
  • ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
  • ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
  • ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer

ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer

Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Split Core Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Multilayer Honeycomb Type
Samples:
US$ 0/5pcs 1 5pcs(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
ZMCTLK80
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Cascade Type
Voltage Transformation Principle
Capacitive Type
Inner Hole Size
80mm
Turns Ratio
2000:1
Rated Primary Current
1A
Rated Continuous Thermal Current
2A
Accuracy
1.0
Transport Package
Outer Carton with Smaller Inner Box
Specification
ISO9001, ISO14001 ROHS, CE, SGS
Trademark
zeming
Origin
China
HS Code
8504311000
Production Capacity
100.000PCS/Month

Product Description

Split residual current transformer ZMCTLK80
 
1. Main technical parameters:
 
Item Sign Technical Parameters Item Sign Technical Parameters
Working frequency f 50Hz-60Hz Line insulation V 1000
Rated primary current In 1A Dielectric strength - 500MΩ/500V/min
Rated secondary output IO 0.5mA Insulation voltage - 3000VAc(r.m.s)(2mA/1min)
Rated load resistance Ω 500
Linearity f <1.5% Operating temperature Ta -12ºC ~ +75ºC
Accuracy class - 1class Storage temperature Ts -20ºC ~ +75ºC
Rated continuous thermal current A 2      
 
2. Definition of primary, secondary and polar end of transformer:
2.1 Definition of  transformer primary and secondary :Transformer primary feedthrough input, secondary lead or terminal output.
2.2 Definition of primary and secondary leads with same polarity:P1-S1Yellow ;P2-S2 Black
2.3 The electrical schematic diagram of the transformer is as follows:

ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
 
3. For dimensions, refer to the following figure
 

ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer

ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
ID80 Split Leakage Current Transformer/ Residual Clamp Current Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now