ZMCT146D-1 Current Transformer
Small size,high accuracy,food consistency,For accurate current and power measurement
Structural parameters:
Front view Bottom view
The main technical parameters:
Model |
ZMCT146D-1 |
input current |
0~100A(sampling resistor 10Ω) |
Rated output current |
10mA at input 10A |
turns ratio |
1000:1 |
phase angle error |
≤20'(Sampling resistor 10Ω) |
linear range |
0~100A(sampling resistor 10Ω) |
linearity |
≤0.5%(5%dot~120%dot) |
Permissible error |
-0.5% ≤ f ≤+0.5%(rated dot) |
isolation voltage |
3000V |
application |
Measurement or protection |
Encapsulation |
Epoxy |
Outer casing material |
Flame retardant PBT |
operating temperature |
-40ºC~+80ºC |
Direction for use:
Figure I Figure II
1.Typical usage is shown in Figure 1 and Figure 2. R is a sampling resistor.
2. Empty pin can not be grounded.