ZMCT113C Current Transformer
Features and applications: Small size, wide linear range,mainly for power automation protection sampling
Structural parameter:
3,4pin: secondary output,1,2pin: empty pin
Front view Bottom view
The main technical parameters:
Model |
ZMCT113C |
Rated input current |
5A |
Rated output current |
2.5mA |
turns ratio |
2000:1 |
phase angle error |
≤60'(input 5A,sampling resistor 20Ω) |
linear range |
0~100A(sampling resistor 20Ω) |
linearity |
≤0.3% (5%dot and 120%dot) |
Ratio error |
-0.5%≤f≤+0.5% (input 5A,sampling resistor 20Ω) |
isolation voltage |
4500V |
application |
power automation protection sampling |
Encapsulation |
Epoxy |
installation |
PCB mounting (pin length >3mm) |
operating temperature |
-40ºC~+70ºC |
Shell material |
ABS (Note: ABS shell is not available for wave soldering) |
Direction for use:
1. ZMCT113C used for protection. Typical usage as shown
2. Empty pin can not be grounded.