ZMCT204D Current Transformer
Features and application: Small size,high accuracy,food consistency,for current and power measurement
Key words: current transformer
Structural parameters:
Front view Bottom view
The main technical parameters:
Model |
ZMCT204D |
input current |
0~10A(sampling resistor 50Ω) |
Rated output current |
5mA at input 5A |
turns ratio |
1000:1 |
phase angle error |
≤15'(input 1A,sampling resistor 50Ω) |
Accuracy class |
0.2 |
linearity |
≤0.2%(5%dot~120%dot) |
Ratio error |
-0.2%≤f≤+0.2%(input 1A,sampling resistor 50Ω) |
isolation voltage |
4500V |
application |
current and power measurement |
Encapsulation |
Epoxy |
installation |
PCB mounting (Pin Length>3mm) |
operating temperature |
-40ºC~+85ºC |
Usage direction:
Figure I FigureII
1. The typical usage of the product is for the active output ( FigureI) . R is a sampling resistor.
2. The product can be directly through the resistance sampling , easy to use (FigureII).