ZEMCT132 Current Transformer
Features: Small size,high accuracy,good consistency
Application: for current and power measurement
Structural parameter:
Front view Bottom view
The main technical parameter:
Model |
ZEMCT132 |
primary current |
0~10A(50Ω) |
secondary current |
5mA at input 5A |
turns ratio |
1000:1 |
phase angle error |
≤15' (input 5A,sampling resistor 50Ω) |
Accuracy class |
0.2 |
linearity |
≤0.2%(5%dot~120%dot) |
Permissible error |
-0.2%≤f≤+0.2% (input 5A,sampling resistor50Ω) |
isolation voltage |
4500V |
application |
Precise measurement of current and power |
Encapsulation |
Epoxy |
installation |
PCB mounting |
operating temperature |
-40ºC~+85ºC |
Direction for use:
Figure I FigureII
1. The typical usage of the product is for the active output (Figure I). R is a sampling resistor, c and r is used for phase compensation.
2. The product can be directly through the resistance sampling, easy to use (FigureII).
3. The instructions are for reference only, specific parameter is subject to specifications (acknowledgment).